Open and Closed Issues for TASKING VX-toolset for RH850 v5.0r1HomeLogin

Patches

Open Issues

This is a list of currently open issues for the TASKING VX-toolset for RH850 v5.0r1. The list may include issues found in later releases, whether such issues also appear in this releasehas not always been verified yet. See below for the list of closed issues. The list of fixed issues for v5.0r1 is included in the release notes of the product.

Problems

IDSummary
RH850VX-944 Incorrect encoding for CALLT instruction
RH850VX-946 Encodings for SYNCE and SYNCM instructions are swapped
RH850VX-950 Erroneous SFR definitions
RH850VX-957 C startup code does not compile for E2x devices when all cores are enabled
RH850VX-963 C compiler c850 processes __attribute__(( section("...") )) and __section__("...") incorrectly
RH850VX-966 Incorrect handling of large struct variadic arguments
RH850VX-967 Using linker symbols may lead to duplicate global symbols with different values
RH850VX-969 Missing integer promotion leads to incorrect result of comparison
RH850VX-970 CRC recognition is not precise enough
RH850VX-971 Widening conversion after addition with constant might lose wraparound behavior
RH850VX-972 Option -Av is not always honored
RH850VX-978 std::exception_ptr comparison and rethrow_exception give incorrect results
RH850VX-979 Incorrect compilation for integer bit-field member
RH850VX-980 Statement expressions can crash the compiler or produce wrong code
RH850VX-981 Derivative LSL files are not supporting macro __NO_HEAP_CLEAR
RH850VX-990 Miscompilation for always-false range checks
RH850VX-992 Floating-point literal parser mis-rounds an exact round-to-nearest-even tie
RH850VX-994 Erroneous values for SFR register offset macros in SFR files for MCS toolset
RH850VX-998 Calls to a weak-aliased symbol are resolved directly instead of at link-time
RH850VX-999 Function merging optimization redirects calls to weak functions

Closed Issues

This is a list of issues that have been closed with a resolution other than fixed. This list contains issues that will not be fixed, issues that appeared to be not a problem and/or issues that could not be reproduced. The list of fixed issues for v5.0r1 is not shown here, it is included in the release notes of the product.

Not a problem

IDSummary
RH850VX-204 Restart button problem when waiting for FSS input
RH850VX-401 Hardware instruction trace sometimes stops

Table of Contents